archive-fr.com » FR » C » CLIMESPACE.FR

Total: 83

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • ClimespaceJe souhaite être contacté par CLIMESPACE - Climespace
    Organismes financiers Salle de spectacle Musées Divers Surface à climatiser m Votre message Informations obligatoires Afin de répondre à toutes vos questions et ou d évaluer l adéquation de l offre CLIMESPACE à votre besoin un conseiller commercial vous recontactera dans les meilleurs délais Merci à vous L équipe CLIMESPACE COORDONNEES CLIMESPACE 3 5 boulevard Diderot 75012 PARIS Tel 01 40 02 78 00 Le leader du rafraîchissement durable à

    Original URL path: http://www.climespace.fr/je-souhaite-etre-contacte-par-climespace/#wpcf7-f611-p612-o1 (2015-12-30)
    Open archived version from archive


  • ClimespacePlan du site - Climespace
    adaptée aux bureaux Témoignage bureaux Une expertise adaptée aux établissements recevant du public Témoignage ERP Une expertise adaptée aux commerces Témoignage Commerce Grand Magasin Une expertise adaptée aux établissements hôteliers Témoignages Hôtels Restaurants Un site en quête de certifications environnementales Témoignage Démarche labellisation thermique Une expertise adaptée aux sites à usages thermiques spécifiques Témoignage site à usages thermiques spécifiques Quels bénéfices pour vous Exprimez vos attentes Localisez votre bâtiment Optimisez

    Original URL path: http://www.climespace.fr/plan-du-site/ (2015-12-30)
    Open archived version from archive

  • ClimespacePrincipe du froid urbain - Climespace
    Survolez le schéma et découvrez les différentes étapes du froid urbain Accueil Climespace Le Froid Urbain La production La distribution La livraison Un processus maîtrisé L Organisation FAQ Mon Climespace

    Original URL path: http://www.climespace.fr/468-2/ (2015-12-30)
    Open archived version from archive

  • ClimespaceDemande d'ouverture de compte - Climespace
    Autre Société Afin de pouvoir donner suite à votre demande merci de communiquer un numéro de contrat dont vous avez la charge et dont vous êtes payeur Vos contrats Informations obligatoires Les informations que vous nous communiquez nous permettent de traiter votre demande Elles sont destinées exclusivement à Climespace Conformément à la loi Informatique et Liberté du 6 janvier 1978 vous disposez d un droit d accès de rectification et

    Original URL path: http://www.climespace.fr/mon-climespace-2/demande-douverture-de-compte/ (2015-12-30)
    Open archived version from archive

  • Climespace GBCLIMESPACE a subsidiary of Engie, the world leader of District Cooling and cold distribution - Climespace GB
    energy distributed Revenue 75 million Euros Responsible cooling CLIMESPACE the leading district cooling system with ISO 50001 OHSAS 18001 Health and Safety and ISO 14001 certifications As a Centre of Expertise within the ENGIE Group CLIMESPACE is at the forefront of innovation in its field and provides its skills and experience to district cooling system projects undertaken throughout the world Connection to the district cooling system allows you to enjoy many benefits while avoiding the problems linked to chilled water production in Paris flexibility and security energy efficiency compactness architectural integration CLIMESPACE is an innovative partner in the implementation of technologies that contribute to a significant reduction of energy consumption and CO 2 emissions In Paris compared to an equivalent fleet of standalone installations the CLIMESPACE system allows for 50 of energy efficiency 35 of electricity consumption 50 reduction in CO 2 emissions 65 reduction in water consumption The CLIMESPACE system uses the natural low temperature of the water from the Seine to cool production equipment all year round During the coldest winter periods CLIMESPACE uses direct flow into the district cooling system this is called free cooling CLIMESPACE is an expert in this technology that allows a significant reduction of energy consumption and CO 2 emissions Supply to the production facilities is assured by electricity guaranteed to be from renewable sources More than 600 customers with 5 million equivalent m cooled CLIMESPACE a concession holder with the City of Paris since 1991 serves the most prestigious Parisian sites which include the headquarters of large companies museums hotels restaurants businesses public authorities and apartment buildings Among its many customers are Allianz AXA BNP Paribas Constructa Crédit Lyonnais Gecina Generali Groupama Natixis Scor or SFL for offices Beaugrenelle the Carrousel du Louvre the Forum des Halles and Galeries Lafayette for shopping

    Original URL path: http://www.climespace.fr/en/climespace-a-subsidiary-of-engie-the-world-leader-of-district-cooling-and-cold-distribution/ (2015-12-30)
    Open archived version from archive

  • Climespace GBDistrict Cooling - Climespace GB
    to urban communal or inter communal development In Paris with CLIMESPACE chilled water is produced by refrigeration plants and distributed through pipes serving buildings outfitted with energy transfer stations Each building consumes the amount of cooling energy required for its own needs The DCS operates in a closed circuit with two conduits one for conveying the 5 C chilled water to the users and the other for the return of 15 C water to the generation plants The DCS thus consists of three basic elements generation plants a distribution network energy transfer stations ETS A smart grid To ensure the continuous supply of cooling and for increased security the generation plants distribution network and ETS are managed from a control centre with human presence 24 7 These connected technologies together achieve continuous improvement in energy efficiency More than 600 energy transfer stations communicate in real time and 102 400 monitoring points are connected to the control centre Principle of CLIMESPACE DCS District Cooling System Map The benefits for our customers Controlling costs Cost structure transparency throughout the building s entire life cycle Elimination of financial uncertainties related to maintenance and repair costs Initial investment costs known Adjustable capacity contract adapted

    Original URL path: http://www.climespace.fr/en/district-cooling/ (2015-12-30)
    Open archived version from archive

  • Climespace GBProduction and storage - Climespace GB
    type bacterial dissemination TAKES THE VIRTUAL TOUR OF THE CANADA PLANT The Tokyo plant Protected environment Located in the basement of the Palais de Tokyo this plant has many advantages The proximity of the Seine actually allows cooling towers to be dispensed with This location favourable to the operation of a plant cooled by water from the Seine has eliminated the need to construct around a hundred stand alone installations and as many cooling towers The environment both in terms of the air quality and the architectural aesthetics of this exceptional area has been well preserved Cooling capacity 52 MW Thanks in particular to a mezzanine style installation the plant occupies an area of 2 200 m 2 in the basement of the Palais de Tokyo created by the excavation of the original crawlspace The museum dedicated to contemporary design has therefore been able to maintain and operate all its noble surface areas This unit includes eight refrigeration units with a total capacity of 52 MW at 0 7 C The main advantages of the site Lack of noise thanks to special purpose insulation No visual impact on operations thanks to the use of water from the Seine No additional traffic generated by site operation No architectural modification of the Palais de Tokyo TAKE THE VIRTUAL TOUR OF THE TOKYO PLANT The Auber plant an extraordinary site The Auber plant integrated with the RER A station was commissioned in 2009 This plant with a capacity of 24 MW can cope with the growing demand for cooling needs in the central Paris business district Infrastructure sharing This plant s installation in the heart of a high traffic station has been possible thanks to the sharing of technical space with the RATP The situation of the plant made site completion particularly complex the presence of the underground train network the routing of materials by rail and at night etc WATCH THE VIDEO The Opera plant In the heart of the Grands Magasins Commissioned in 1994 this plant is located in the basement of Galeries Lafayette The power of this plant dedicated to chilled water production is 33 MW It includes 9 refrigeration units and ice storage The Opera plant has a cooling system using cooling towers The Etoile plant Managing peak demand Since 1999 the Etoile plant has been installed in the basement of the SCOR building located on Avenue Kleber The fruit of a conversion of an independent production unit it is inter connected with the Centre network with an installed cooling capacity of 8 MW In 2006 it was completely renovated and includes 2 cold units This plant is cooled by air cooling towers equipped with anti steam plume batteries and produces during peak periods and high temperature conditions The Bercy plant Serving a changing neighbourhood Installed in 1993 in the 12th arrondissement near the Gare de Lyon this plant supplies the Eastern network known as the Bercy network It was created to supply the Paris Rive Gauche area Development

    Original URL path: http://www.climespace.fr/en/district-cooling/production-and-storage/ (2015-12-30)
    Open archived version from archive

  • Climespace GBDistribution - Climespace GB
    16th arrondissements A second network named the Bercy network serves the 12th and 13th arrondissements A network more than 70 km long The entire CLIMESPACE network is made up of two separate pipelines one outgoing line that brings chilled water to customers distribution stations the other return line taking warmed water to the production plants The temperature of the chilled water supplied via the outgoing line from the production unit ranges from 1 to 4 C The return water comes back between 12 and 14 C Entirely underground the network utilizes the Paris sewage infrastructure or circulates beneath public right of ways Interconnected the network is subject to regular daily monitoring The CLIMESPACE system offers all customers wide flexibility of use and service reliability A smart grid To ensure the continuous supply of cooling and for increased security the generation plants distribution network and ETS are managed from a control centre with human presence 24 7 These connected technologies together achieve continuous improvement in energy efficiency More than 600 energy transfer stations communicate in real time and 102 400 monitoring points are connected to the control centre The leader in sustainable cooling in Paris Expertise tailored to your business What

    Original URL path: http://www.climespace.fr/en/district-cooling/distribution/ (2015-12-30)
    Open archived version from archive